CO Combustor unit

De Jong Combustion has delivered one (1) CO-Combustor unit, complete with supplementary fuel gas burners, fuel trains and burner management system.

DESIGN BASIS for CO COMBUSTOR
Flue gas flow : 548.200 Nm3/hr
Flue gas inlet temperature : 739 °C
Max CO content at inlet : 5,31 vol-%
Minimum Oxygen content at outlet :2 vol-%

 

Complete with
Refractory lining
Inlet for Flue Gas
Inlets for primary combustion air
Inlet for secondary air
3 Register burners c/w igniter & scanners
Optimum air & CO gas distribution for complete conversion of CO into CO2.

KEY DESIGN DATA
Diameter : 8,5 m
Overall length : 17,500 m
Weight : 175 tonn
Burner capacity : 3 x 64 MW
Furnace temperature : 982 °C
Max Fuel gas consumption : 19.500 Nm3/hr
Max air flow : 470.000 Nm3/hr

EMISSION GUARANTEES
The emission at the Combustor outlet will not exceed:
CO : 120 ppmV, ref. 3% O2 dry basis
NOx : 350 mg/nm3, ref. 3% O2 dry basis

Note: The NOx emissions are applicable for RFG mode based without considering the NOx content in the RFG.

 


Burner data

Name
Location
Scope
No. of installations
Design capacity
Fuel type
Burner type
Application
Boiler manufacturer

ARAK
Iran
CO-combustor with register burner, fuel trains & BMS
1
192 MW
Natural gas
Register burners
CO oxydiser
NEM Hengelo